Send Message
Wuhan Desheng Biochemical Technology Co., Ltd
Wuhan Desheng Biochemical Technology Co., Ltd
products
Home /

products

What are the solvent requirements when preparing the biological buffer TAPS CAS 29915-38-6?

Product Details

Place of Origin: hubei

Brand Name: desheng

Certification: ISO9000

Model Number: AR

Payment & Shipping Terms

Minimum Order Quantity: 20kg

Price: Detailed discussion

Packaging Details: 25kg / barrel

Delivery Time: 3 days

Payment Terms: L/C, T/T, D/P, Western Union

Supply Ability: 1t / day

Get Best Price
Contact Now
Specifications
Highlight:

CAS 29915-38-6 Biological Buffer

,

TAPS CAS 29915-38-6

,

TAPS Biological Buffer

CAS:
29915-38-6
Appearance:
White Powder
Packaging:
25kg / Barrel
Alias:
TAPS
CAS:
29915-38-6
Appearance:
White Powder
Packaging:
25kg / Barrel
Alias:
TAPS
Description
What are the solvent requirements when preparing the biological buffer TAPS CAS 29915-38-6?

In biological and medical experiments, biological buffering agents play a crucial role in maintaining the stability of the experimental environment, ensuring the accuracy and reliability of experimental results. TAPS buffer, as a commonly used non-ionic amphoteric buffer, has good buffering capacity and is widely used in fields such as flow cytometry analysis. However, the selection and treatment of solvents are crucial when preparing TAPS solutions, as they directly affect the purity and effectiveness of the buffer solution. So, what are the requirements for solvents when preparing TAPS buffers?

 

Product full name N-Ethyl-N-(3-sulfopropyl)anilinesodiumsalt
Product abbreviation TAPS buffer
CAS number 29915-38-6
Storage conditions Room temperature, away from light and moisture
purpose Used as a commonly used buffer system in DNA screening systems, etc
Product advantages Purity>99%, good water solubility, stable process
Manufacturer Hubei Xindesheng Material Technology Co., Ltd

 

Purity requirements for solvents


1.1 Use ultrapure water or deionized water


When preparing TAPS solution, high-purity solvents should be selected first. Ultra pure water or deionized water is an ideal choice because they remove most of the ions, organic matter, and microorganisms in the water, ensuring the purity of the solvent. The use of these solvents can effectively avoid the influence of impurities on the performance of TAPS buffer solution, ensuring the accuracy of experimental results.

 

What are the solvent requirements when preparing the biological buffer TAPS CAS 29915-38-6? 0

TAPS Powder


1.2 Avoid using regular tap water


Ordinary tap water contains various minerals, chloride ions, and other dissolved substances. These impurities will react with TAPS during the preparation process, affecting the pH value and buffering capacity of the buffer solution. Therefore, when preparing TAPS solution, it is necessary to strictly avoid using ordinary tap water as a solvent.

 

Handling and storage of solvents


2.1 Pre treatment of solvents


Before preparation, the selected solvent should undergo necessary pretreatment. For example, ultrapure water or deionized water should be thoroughly filtered and degassed before use to remove any small particles and dissolved gases that may be present. These processing steps help improve the purity of the solvent and ensure the quality of TAPS solution preparation.


2.2 Storage conditions for solvents


The prepared TAPS solution is sensitive to light and temperature, so special attention should be paid to the storage conditions of the solvent. Ultra pure water or deionized water should be stored in clean, sealed containers to avoid contamination and evaporation. We recommend that the solvents used be pre treated before preparing TAPS buffer to ensure their purity.

 

Operating requirements for solvents during the preparation process


3.1 Accurate weighing


When preparing TAPS solution, the amount of TAPS powder and solvent should be accurately weighed according to experimental requirements. Use an electronic balance for precise weighing to ensure the accuracy of the weighing results. Meanwhile, attention should be paid to avoiding powder scattering and loss to ensure that the concentration of the prepared TAPS solution meets the experimental requirements.


3.2 Adequate dissolution


After adding the weighed TAPS powder to the solvent, it should be thoroughly stirred using a magnetic stirrer or vortex oscillator until the powder is completely dissolved. During the stirring process, attention should be paid to observing the color and transparency of the solution to ensure that there is no turbidity or precipitation. If turbidity or precipitation occurs, it may be due to incomplete dissolution of the powder or the presence of impurities, and should be re prepared.


3.3 Filtration and sterilization


The prepared TAPS solution should be filtered and sterilized before use to remove microorganisms and impurities from the solution. Disposable syringes or filters can be used for filtration operations to ensure the purity and sterility of the solution. The filtered TAPS solution should be stored in clean glass bottles and kept in a low-temperature environment.

 

What are the solvent requirements when preparing the biological buffer TAPS CAS 29915-38-6? 1

Product packaging


Hubei Xindesheng Material Technology Co., Ltd. has a history of 19 years since its establishment in 2005. During this period, it has never given up on the research and development of biological buffering agents, and the pursuit of excellent quality is the goal of every Desheng employee. In addition to TAPS buffer, there are dozens of biological buffering agents available for selection, such as tris, bicine, mops, etc. If you also need to purchase biological buffering agents, please feel free to contact me or click on the official website for more details!

 

 

Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send