Precautions For Using Chemiluminescence Reagent Acridine Salt NSP-SA-NHS 199293-83-9

Product Details

Place of Origin: hubei

Brand Name: desheng

Certification: ISO9000

Model Number: AR

Payment & Shipping Terms

Minimum Order Quantity: 10mg

Price: Detailed discussion

Packaging Details: 10mg / bottle, 50mg / bottle,500g / bottle,

Delivery Time: 5 days

Payment Terms: L/C, T/T, D/P, Western Union

Supply Ability: 10 g / week

Get Best Price
Contact Now
Specifications
Highlight:

199293-83-9 Chemiluminescence Reagent

,

Acridine Salt Chemiluminescence Reagent

,

NSP-SA-NHS Chemiluminescence Reagent

Purity:
>98%
Exterior:
Yellow Solid Or Powder
Smallest Packaging:
10mg/bottle
Save:
Refrigerated At 2-8 ℃, Sealed, Dry, And Stored In A Dark Place
CAS:
199293-83-9
Purity:
>98%
Exterior:
Yellow Solid Or Powder
Smallest Packaging:
10mg/bottle
Save:
Refrigerated At 2-8 ℃, Sealed, Dry, And Stored In A Dark Place
CAS:
199293-83-9
Description
Precautions For Using Chemiluminescence Reagent Acridine Salt NSP-SA-NHS 199293-83-9

The chemiluminescent reagent NSP-SA-NHS (CAS number: 199293-83-9) is widely used in labeling proteins, peptides, antibodies, nucleic acids, and other fields as a stable and sensitive chemiluminescent reagent. However, when using acridine salt NSP-SA-NHS, a series of precautions must be strictly followed to ensure the accuracy of experimental results and the stability of reagents. The following will provide a detailed introduction.

 

Product Name Acridine salt NSP-SA-NHS
CAS number 199293-83-9
Product appearance Yellow solid or powder
Storage conditions Refrigerate at 2-8 ℃, seal, dry, and store away from light
Product advantages Has good water solubility, stable process, and small inter batch differences, etc
Manufacturer Hubei Xindesheng Material Technology Co., Ltd

 

1, Packaging and storage conditions


Sealed and dark proof: Acridine ester NSP-SA-NHS must be stored in a well sealed, opaque dark bottle. Due to the sensitivity of the reagent to light, light exposure can cause partial decomposition, thereby affecting the luminescence effect. Therefore, it is necessary to strictly avoid light during the experimental process and product storage.

 

Precautions For Using Chemiluminescence Reagent Acridine Salt NSP-SA-NHS 199293-83-9 0

Acridine ester NSP-SA-NHS powder


Low temperature storage: Acridine ester NSP-SA-NHS needs to be stored at low temperatures to prevent moisture absorption and deterioration. It is recommended to store the reagents in the refrigerator and regularly check the sealing to ensure that the reagents are not damp.


2, Dissolution and labeling


Solvent selection: Acridine ester NSP-SA-NHS can be dissolved in non protonic solvents such as anhydrous DMSO. Before labeling, due to the activation of the carboxyl group at the end of the acridine ester by NHS, it is more active and should be dissolved using non protonic dry anhydrous solvents.


Marking process: After marking, acridine ester exists in the form of amide or ester bonds with the labeled substance, and acidic solvents have little effect on the labeled substance. However, due to the instability of the active sites of acridine esters in alkaline and oxidative environments, corresponding non strong alkaline and non oxidative systems should be prepared based on the stability of the labeled substance for processing and preservation.


3, Experiment and Testing


The luminescence process is brief: The luminescence process of acridine ester NSP-SA-NHS is very brief, with the entire process occurring in less than 2 seconds. Therefore, when triggering the luminescence condition, it is necessary to prepare detection instruments in advance, such as internal photometers and photon detectors, to capture key information and ensure the accuracy of experimental and detection results.


Separation and purification: When labeling large molecular compounds such as proteins, it is recommended to use a G25 desalination column for separation; When labeling small molecule compounds, it is recommended to use column chromatography for separation. These separation methods can effectively remove unlabeled reagents and impurities, and improve the purity of labeled substances.


4, Stability and safety


Stability impact: The stability of acridine ester NSP-SA-NHS is greatly affected by temperature, pH value, and oxidation environment. The higher the temperature, pH value, and oxidation environment, the higher the degree of hydrolysis of the reagent, and the lower its stability. Therefore, during storage and experimentation, these conditions should be strictly controlled to extend the service life of the reagents.


Safety precautions: Although the toxicity of acridine ester NSP-SA-NHS is relatively low, safety precautions should still be taken during use. It is recommended to wear personal protective equipment such as protective goggles, gloves, and masks to avoid direct contact of reagents with the skin and eyes. At the same time, good ventilation conditions should be maintained during the experiment to prevent the volatilization of reagents from causing harm to the human body.

 

Precautions For Using Chemiluminescence Reagent Acridine Salt NSP-SA-NHS 199293-83-9 1

Product packaging


Hubei Xindesheng Material Technology Co., Ltd. has professional experimental equipment, production equipment, and technical talents. It has a history of nearly 20 years in the research and development of various