Product Details
Place of Origin: hubei
Brand Name: desheng
Certification: ISO9000
Model Number: Blood collection tube additive
Payment & Shipping Terms
Minimum Order Quantity: 20kg
Price: Detailed discussion
Packaging Details: 20kg / box or 25kg / box
Delivery Time: 5 days
Payment Terms: L/C, T/T, D/P, Western Union
Supply Ability: 30t / month
Product Name: |
Heparin Lithium |
Model: |
Blood Collection Tube Additive |
Packaging Specifications: |
50g/bottle |
Appearance: |
White Powder |
Product Name: |
Heparin Lithium |
Model: |
Blood Collection Tube Additive |
Packaging Specifications: |
50g/bottle |
Appearance: |
White Powder |
Heparin lithium, as a commonly used anticoagulant, is widely used in various blood collection tubes. However, the pH value of heparin lithium has a significant impact on its anticoagulant effect and the stability of blood samples. This article will delve into the factors that affect the pH value of heparin lithium, a blood collection tube additive, in order to provide reference for relevant researchers.
Product Name | Heparin lithium |
Product appearance | White amorphous powder |
Product performance | Easy to dissolve in water, hygroscopic, with an average molecular weight of 15000, stable at room temperature |
Product potency | Heparin lithium potency ≥ 150IU/mg, anhydrous potency ≥ 160IU/mg |
Packaging specifications | 10g/bottle, 20g/bottle, 50g/bottle |
Storage conditions | Store in a cool and dry place, sealed and away from light, and avoid moisture |
Manufacturer | Hubei Xindesheng Material Technology Co., Ltd |
The role of lithium heparin in blood collection tubes and the importance of pH value
Heparin lithium, as an anticoagulant in blood collection tubes, mainly binds to thrombin in the blood to prevent its activity, thereby preventing coagulation of blood samples during collection and storage. The pH value of heparin lithium plays a crucial role in this process. A suitable pH value can stabilize the activity of heparin lithium, thereby exerting its anticoagulant effect.
lithium heparin
Factors affecting the pH value of heparin lithium
1. Purity and concentration of lithium heparin. The purity and concentration of lithium heparin are one of the key factors affecting its pH value. High purity lithium heparin can reduce the interference of impurities on pH value and maintain its stability. At the same time, appropriate concentration is also an important condition for heparin lithium to exert good anticoagulant effects. Excessive or insufficient concentration may affect the pH value of heparin lithium, thereby affecting its anticoagulant effect.
2. The types and concentrations of ions in the solution. Heparin lithium usually exists in aqueous solution, and the type and concentration of ions in the solution have a significant impact on its pH value. For example, an increase in acidic ions such as hydrogen ions (H+) will cause a decrease in the pH value of the solution, while an increase in alkaline ions such as hydroxide ions (OH -) will cause an increase in pH. Therefore, when preparing heparin lithium solution, it is necessary to control the type and concentration of ions in the solution to maintain a stable pH value.
3. Temperature and storage conditions. Temperature and storage conditions are another important factor affecting the pH value of heparin lithium. High temperature environment may cause thermal decomposition or oxidation reactions of heparin lithium molecules, thereby changing their pH value. In addition, factors such as humidity and light in the storage environment may also affect the pH value of heparin lithium. Therefore, when storing heparin lithium, a cool, dry, and dark environment should be chosen, and its pH value should be checked regularly.
4. Interaction with other additives. In addition to heparin lithium, other additives such as preservatives and stabilizers may also be added to the blood collection tube. These additives may interact with lithium heparin, thereby affecting its pH value. For example, certain preservatives may undergo complexation or ion exchange reactions with lithium heparin, leading to changes in the pH value of the solution. Therefore, when selecting and using additives, it is necessary to fully consider their interactions with each other.
5. Production process and quality control. The production process and quality control are the fundamental factors affecting the pH value of heparin lithium. During the production process, improper control of parameters such as temperature, pressure, and time, or substandard raw material quality, may cause changes in the pH value of heparin lithium. Therefore, in the production of heparin lithium, it is necessary to choose high-quality raw materials, optimize production processes, strengthen quality control and other measures to stabilize the pH value of heparin lithium.
Product packaging
Hubei Xindesheng Material Technology Co., Ltd. has been researching and producing heparin lithium and other blood collection tube additives for nearly 20 years. With rich production experience, we ensure that all indicators of our products meet relevant standards. If you have any purchasing needs in the near future, please click on the Desheng official website for more details or contact me!